Bionix analyzer reads biomethane quality every second at grid injection
BioBasic's Bionix online analyzer reports CH₄, CO₂, O₂ and H₂S at the biomethane grid injection point every second — roughly 11 minutes faster than a process GC in a six-day field trial.

SPECIFICATION
- 1
BioBasic Bionix reports CH₄, CO₂, O₂ and H₂S once per second at the RNG grid injection point
- 2
Six-day field comparison: mean deviation from process GC below 0.3 vol.% for CH₄
- 3
The analyzer showed gas changes about 11 minutes earlier on average than the GC
- 4
Measurement methods: dual-beam NDIR (CH₄/CO₂), NDUV (H₂S), electrochemical (O₂)
- 5
Maker is based in Herten, Germany; unit is positioned as a lower-cost complement to the GC
A one-second reading cycle is the headline number behind the BioBasic Bionix, an online gas analyzer built to monitor biomethane (RNG) quality right at the grid injection point. Where a process gas chromatograph delivers a value only every few minutes, the Bionix reports CH₄, CO₂, O₂ and H₂S once per second.
That speed difference matters at the injection point. Gas quality at a biomethane facility shifts with feedstock and upstream process upsets, and an operator who sees a compositional drift eleven minutes sooner has a better shot at correcting it before off-spec gas reaches the grid. In a six-day field comparison, the Bionix detected changes about eleven minutes earlier on average than the process GC — the exact figure depending on the GC cycle time and sample line configuration.
How accurate is it against the GC?
The same six-day field comparison put the mean deviation from the process GC below 0.3 vol.% for methane. That is not GC-grade equivalence across all components, but for continuous monitoring duty the numbers hold up well enough that BioBasic positions the unit as a complement to the GC rather than a replacement — at what the company describes as a significantly lower cost.
The takeaway for plant engineers: you keep the GC as your reference method, and you add a fast, cheaper continuous reading in between GC cycles.
What sensing technology is inside?
Each parameter gets its own dedicated measurement principle:
- CH₄ and CO₂ — dual-beam NDIR (non-dispersive infrared)
- H₂S — NDUV (non-dispersive ultraviolet)
- O₂ — electrochemical cell
Dual-beam NDIR is the standard workhorse approach for bulk methane and carbon dioxide in biogas service; the second beam provides the reference channel that keeps the reading stable as the source lamp ages. NDUV for hydrogen sulfide handles the trace-level sulfur component that decides whether the gas passes grid sulfur limits.
How does it fit an existing plant?
The analyzer arrives with the interface options most control rooms already run. Standard or optional features include:
- Automatic, error-monitored calibration
- Color touchscreen for local operation
- USB data logging
- Bluetooth app for mobile access
- 4–20 mA, RS232 and fieldbus outputs
The automatic calibration with error monitoring is the practical point here: at an unattended injection station, an analyzer that flags its own failed calibration beats one that silently drifts. The fieldbus and 4–20 mA outputs mean the one-second readings can land directly in the plant DCS or SCADA without intermediate hardware, and the Bluetooth app gives a commissioning or service technician local visibility without pulling a laptop into the cabinet.
The unit is made in Herten, Germany.
What it changes at the fence line
For operators feeding RNG into the gas grid, the Bionix narrows the blind window between GC cycles from minutes to a single second — at a cost point well below adding a second chromatograph.